When does sureops pause?
sureops pauses for approval at the following trigger points:Post-diagnosis: recommendation approval
After the Diagnosis Specialist produces root cause analysis and proposes remediation actions, the agent pauses before any fix is attempted — unless your org has opted into autonomous execution for that incident (off by default; see Supervised vs Self-Driving). This is the primary gate in the incident pipeline. The approval request includes:- The proposed root cause(s) with confidence scores
- Each recommended action with its risk classification
- The executor for each action (runtime execution vs. fix PR vs. human)
- Supporting evidence (metric data, log excerpts, trace analysis)
P1 / P2 severity incidents
Critical and high-severity incidents have additional approval requirements, even in Self-Driving mode. The agent cannot auto-execute anything for a P1 or P2 incident regardless of your Auto-execute low / medium-risk fixes (autonomous_execution) settings.
High-risk or destructive actions
A high-risk action always pauses for human approval. No autonomy setting can lift that — there is no configuration in which sureops executes a high-risk action unattended. An action also counts as high-risk when sureops can’t classify its risk: an absent or unrecognized risk label is treated as high and gated, rather than assumed safe. High risk is one of five hard carve-outs that always require explicit human approval, regardless of mode or auto-approve settings, and none of which can be turned off:- P1/P2 severity incidents (above).
- Any recommendation that opens a fix PR (below).
- Any high-risk action the agent would execute — rollbacks that affect production traffic, scaling operations above a defined threshold, configuration changes to security-sensitive surfaces, or anything the diagnosis agent marks as potentially irreversible — plus anything whose risk couldn’t be classified. (Risk gating applies to recommendations the agent would actually run. A recommendation whose outcome is “escalate to a human” or “monitor only” carries no agent action, so its own risk label doesn’t gate the batch. Separately, a batch made up entirely of escalate hand-offs skips the approval queue and goes straight to a human.)
- Any diagnosis rebuilt from incomplete evidence — a rare safeguard that only fires when a diagnosis run was interrupted mid-flight. Such a run never completed a full synthesis pass, so its recommendations always reach a human.
- Any diagnosis started from the stage card while someone holds control (Re-run, Continue or Back into Diagnosis, or a budget reset) — its recommendations always wait for a human decision, even if your org auto-approves or auto-executes.
- Auto-execute low / medium-risk fixes (
autonomous_execution), the default path when auto-approve is off — recommendations auto-execute only when every recommendation the agent would run is at or below your configured ceiling. The ceiling is evaluated batch-level, not per recommendation: if any one of them exceeds it, the whole batch waits for your approval rather than executing the rest. - Auto-approve agent actions (
auto_approve_hitl) — approves pending recommendations up to and including medium risk. It is the more permissive of the two, but it does not disable the risk gate: high-risk and unclassifiable actions still pause. These two settings are mutually exclusive — the risk-ceiling logic above only runs when auto-approve is off.
Fix-PR recommendations always gate
Any recommendation that opens a fix PR against your GitOps repository always pauses for human review — even if your org has auto-approve or autonomous execution turned on. A fix PR mutates your source repository on merge, so you always see the draft diff before it can be approved. This is a hard-coded safety carve-out, not a configurable option.What an approval request looks like
In-app
Pending approvals appear in two places:- Command Center → Pending Approvals panel — a list of all open approval requests across all active incidents.
- Incident detail page → Recommendations section — inline approve/reject controls with full context.
- The incident and its severity
- The proposed action and its description
- Its risk label
Slack notification
If you have Slack connected, sureops posts an approval request to the incident’s war-room channel, if it has one — by default only P1/P2 incidents get a war room (see Incident channels). The message includes:- Incident name and link
- The proposed action summary
- Approve and Reject buttons (requires the sureops Slack app)
approvals:grant capability (Commander, Admin, Owner) when an approval request is created — this is independent of Slack, not a fallback triggered by a Slack timeout. Email notifications for approval requests are opt-in and disabled by default: each user enables them individually in their notification preferences. If you’re relying on email as a safety net for missed Slack approvals, confirm the relevant users have opted in — otherwise no email will be sent.
Who can approve?
Approvals require theapprovals:grant capability, which is granted to:
- Commander
- Admin
- Owner
Timeout behavior
Approval gates have a configurable timeout. When a gate goes unanswered, sureops acts according to thehitl_timeout_action setting for your environment.
The gate timeout duration is configured in Settings → General, in the “Approval Timeout” card (“Timeout (minutes)” field). The same Approval Timeout also limits how long an incident waits on hand-offs to a person; see Hand-offs wait at Resolution. The
hitl_timeout_action behavior itself (escalate / extend / auto_decide) is not exposed in the UI today — it’s API-only, so ask your onboarding contact to change it.
HITL gates by mode
Both Self-Driving and Supervised modes have gates, but the set differs.Self-Driving mode
Gates fire at the specific triggers listed above: post-diagnosis recommendation approval, plus the five hard carve-outs — P1/P2 severity, fix-PR recommendations, high-risk or unclassifiable actions, diagnoses rebuilt from incomplete evidence, and diagnoses started from the stage card while someone holds control — none of which any auto-approve setting can bypass (see “High-risk or destructive actions” above). Auto-approve settings can reduce the number of gates for lower-risk actions on P3/P4 incidents. See Supervised vs Self-Driving for configuration details.Supervised mode
In Supervised mode, detection and triage still run automatically with no gate — the difference from Self-Driving is the post-diagnosis gate: every batch of recommendations pauses for your explicit approval before resolution runs, with no auto-approve bypass available. The five hard carve-outs above apply here too, though in practice they change nothing: nothing auto-approves in Supervised mode to begin with. Supervised mode does not, by itself, stop the incident after every stage — that’s a separate axis. If you want the incident to pause after every stage so you can inspect it before it advances, take direct control of the incident (Take Control, available in either mode) rather than relying on the mode setting — see Supervised vs Self-Driving.What happens if no one approves
When a gate times out and the action isescalate:
- The incident moves to a waiting for human state
- The graph is suspended — no further agent actions run
- The approval is marked expired: it leaves the Pending Approvals panel and can no longer be approved or rejected
- Any team member with the Responder role or above can take over the incident and resume it
- An unclaimed incident stays waiting until someone with the Responder role or above takes it over
Mixed approval batches
When the Diagnosis Specialist proposes multiple recommendations, you can approve some and reject others. A few rules apply:- An approval can only select recommendations that belong to it. A decision that names a recommendation outside that approval is refused, and nothing is recorded. Refresh the approval and decide again.
- You cannot approve both an execute-fix recommendation and a reinvestigate recommendation in the same batch. These have opposite meanings (act vs. dig deeper), so the system forces you to choose one direction.
- Approving a
reinvestigaterecommendation sends the agent back to the Diagnosis stage with focus on what you flagged. The maximum number of re-investigation rounds is configurable (default: 2) to prevent infinite loops. - Each approved recommendation’s intent determines the routing:
execute_fixproceeds to resolution;reinvestigatereturns to diagnosis;monitormoves to a watch-and-wait closure;escalatesuspends to human takeover.